Welcome to AIRMYTH website!
+86-757-83683732
Banner
Full DC Inverter Vrf System Central Air Conditioner

Full DC Inverter Vrf System Central Air Conditioner

Variable refrigerant flow (VRF), also known as variable refrigerant volume (VRV), is an HVAC technology.

After years of production practice, combined with reasonable suggestions from users, we continue to update, improve and perfect the original High ESP Ducted Fan Coil Unit, Air Cooled Scroll Chiller, Air Conditioning Straight Tube. The products are now sold throughout the country and exported to many countries and regions. Our company is constantly participating in international competition. What attracts us is the opportunity of emerging markets and the necessity of meeting the needs of customers. We believe that any outstanding technology, product and service can only be recognized by customers and create value for customers if the quality is excellent. Our business performance has been breaking new records, and the quality of corporate development has been steadily improved and enhanced. Base on the business concept of Quality first, we would like to meet more and more friends in the word and we hope provide the best product and service to you.

file0001


Variable refrigerant flow (VRF), also known as variable refrigerant volume (VRV), is an HVAC technology. Like ductless mini splits, VRFs use refrigerant as the cooling and heating medium. This refrigerant is conditioned by a single or multiple condensing units (which may be outdoors or indoors, water or air cooled), and is circulated within the building to multiple indoor units.VRF systems, unlike conventional chiller-based systems, allow for varying degrees of cooling in only certain areas, reducing energy consumption.

VRF system outdoor units have all inverter driven compressors. This means their speed can be varied simply by changing the frequency of power supply to that compressor. As the speed changes, so does the amount of refrigerant delivered, allowing the compressor to operate continuously rather than repeatedly cycle on and off. There are two types of VRF systems: heat recovery and heat pump. The biggest difference is that heat recovery units can heat and cool at the same time, while heat pump units can only heat or cool at once. So, heat recovery systems, which improve efficiency by taking heat from one space and redistributing it to another, are ideal for anywhere you need zone-by-zone control—like a hotel or assisted living facility. And heat pump systems are great for spaces where only one mode of operation is needed, like a bank.As the speed changes, so does the amount of refrigerant delivered, allowing the compressor to operate continuously rather than repeatedly cycle on and off.


AMV X Multi inverter vrf system

All DC Inverter Technology;All DC Inverter Compressor;Technology of Maximum Torque Control with Minimum Current; 180° Sine Wave DC Speed Varying Technology; Sensorless DC Inverter Fan Motor; Non-polar CAN technology;88HP Max Capacity;


Features:

1.All DC inverter technology to improve compression efficiency

file0004


All DC inverter compressor and high-performance high pressure chamber are adopted to reduce loss of overheat and improve compression efficiency from direct intake. Compared with low pressure chamber, the compression efficiency is improved. High-efficient permasyn motor is adopted to provide better performance than traditional DC inverter compressor.


2. Sensorless DC inverter fan motor

file0005


Stepless speed regulation ranges from 5Hz to 65Hz.Compared with traditional inverter motors, the operation is more energy-saving.


3.Technology of maximum torque control with minimum current

file0006


It can reduce energy loss caused by device winding so as to realize higher efficiency.


4.Low-frequency torque control

file0007


It can directly control motor torque, through which fan motor can run at a low speed. Users will feel more comfortable while requirements of the system are also met.


5.180° sine wave DC speed varying technology

file0008


It can satisfy various places’ demands for different temperature and is able to save a great deal of electricity and provide users with utmost comfort at the same time.


6.6 basic modules to meet different requirments.128HP max capacity-the largest free combination.

6 basic models.from 8HP to 32HP

file0009


Max capacity of single outdoor unit reaches 32HP and max combination capacity is even up to 128HP, in an industry leading level.

file0010


7.Non-polar CAN technology to improve communication efficiency

file0011


We adopt non-polar CAN communication technology in the industry. CAN communication technology provides quicker system response speed, more convenient installation debugging and more reliable communication data.


8.Wide range of voltage and operation condition

file0012


Working voltage range of AMV X system has been improved to 320V-460V, which surpasses the national standard of 342V-420V. For places with unsteady voltage, this system can still be running well.


9.Wider applicable location

file0013


AMV X can realize a combination of 4 outdoor unit modules connecting with as many as 80 indoor units. It’s especially applicable for business building or hotels.


10.Refrigerant storage and distribution

file0014


The AMV X system is designed without liquid receiver and the excess refrigerant is stored in the piping, which can minimize the refrigerant charging volume and enhance the control accuracy of refrigerant.


11. Long pipe & height difference

1.The total pipe length: 1000 m.
2.The longest pipe length: 200 /240m.
3.Height deference:Outdoor unit. Above<90m<90m.4.Outdoor unit below<110m.
5.Height difference between indoor units: 30m.
6.Length from first indoor distributor to last indoor unit 90 m.
7.Communication wire length can be upto 1000m.

file0015


12. Wide outdoor operation range(380v)

Max.cooling operating temperature is up to 55°C.

Low ambient temperature of cooling mode can be downto-10℃.

file0016


13.World famous brand DC Inverter compressor

High efficiency Oilseparate structure,High efficiency DC Fan Motor,Middle partition Improve the efficiency;Reduce quality.Highefficiency Gas-liquid separater,Low noise design of cylinder to reduce noise when exhaust high pressure gas,Low deformationcylinder design to improve the lifetime,High efficiency Movement oil supply mechanismto Ensure oil supplyand reduce noise.

file0017


14. Service window on front cover

Thanks to the service window, checking outdoor unit's status and setting is now easy, no need to remove the front cover

file0018


15.Certificates.

file0019


16.More than 11 different indoor unit can be connected with outdoor unit.


We have many partners at home and abroad, and enjoy a high reputation in the industry of Full DC Inverter Vrf System Central Air Conditioner. We focus on every link and detail quality control in the production process to ensure stable product quality. Our team has unlimited capabilities and rich experience in helping customers develop solutions, deliver on time and improve quality requirements. We also strive to help our customers achieve the anticipated results and reduce costs, so as to make a win-win situation for botn parties.

Hot Tags: vrf dc inverter air conditioner, China vrf dc inverter air conditioner manufacturers, suppliers, factory, R22, Square Ceilingdiffuser, Ceiling Type Air Conditioner, Ceiling Concealed Fan Coil Unit, Multi Split Inverter Air Conditioner, Air Purifier

Related Showrooms